TD3 PRO teknisk specifikation

Power: 220-240 Vac 50-60 Hz vers. 230 V – 100-130 Vac 50-60 Hz vers.115 V
Maximum power: 3000 W
Insulation: grounded metallic parts TD1 PRO control and setting display on/off switch fault signaller PID electronic control panel pressure gauge heater element
Power adjustment system: TRIAC driven by electronic controller with built-in PID algorithm based on the thermocouple in the heater
Maximum temperature control system on the resistances: TRIAC driven by thermocouple near the resistances; safety thermostat
Electrical protections: 16A fuse, 500 mA, 6.3A for vers 230 V – 1A and 8A for vers 115 V
Regeneration duration: Max 4 h.
Admitted temperature field: from 19° to 70°C – from 66°F to 158°F
Maximum input pressure: 8 bar/116 PSI
Maximum flow: >1200 l/min @ 6 bar – > 42,37 cfm@87 PSI
Air purification: – first condensation separator stage with 25 micron mesh filter; automatic “heavy duty” condensation drain;- second coalescent de-greaser stage with 0,01 micron mesh filter; 99,99999% solid particle retention efficiency; <0.01 mg/m3 maximum oil residue; manual oily condensate drain;- absorption dryer third stage with silica gel: <1.2% residual humidity; < -30°C dp – < -22°F dp output air dew point temperature;- active carbon fourth stage for gaseous pollutant removal such as oily fumes, hydrocarbons and odours; <0.003 mg/m3 maximum oil residue; generates breathable air.
Working pressure regulation: membrane pressure regulator with pressure gauge downstream from filtering elements.

Remote control (optional)

The Walcom® TD3PRO -TD1PRO may be remotely controlled thanks to an optional remote control kit (photo 8). Thanks to these 3-button remote controls, 3 different temperature settings can be used by simply pressing the relevant buttons. We suggest you always use three different temperature during the complete paint cycle to optimise the results that can be achieved during the base application phase, the subsequent drying phase and ending with the last transparent application phase. For example, we suggest the base is applied at 42°C/109°F, then raised to 70°C/158°F to dry the base and, lastly, lowered to 50°C/122°F for the last transparent application phase.

The remote control is thus set to work at these recommended temperatures:
key 1 = 42°/109°F for the base
key 2 = 50°/122°F for the transparent
key 3 = 70°/158°F for drying
These temperatures can be changed and reset according to need in the SETPOINT menu (see paragraph “preliminary settings”) NB:
The TD3PRO -TD1PRO red indicator light will blink to confirm reception whenever a button is pressed on the remote control
Remote control button 1 is associated with Setpoint 1, button 2 with Setpoint 2 and button 3 with Setpoint 3
For further information, see the remote control kit manual.